Hydraulics International, Inc. is one of the world’s leading manufacturers of both military and commercial aircraft ground support equipment (GSE) including the supply of FA-50 (Aviation Ground Support Equipment).
FA-50 (Aviation Ground Support Equipment)
*
Diesel Driven Model: MHU-83D/E replaces MJ-4 Jammer
P/N: 971480-70 (NSN: 1730-01-446-2422)
Electric Driven Model: MHU-83/E
P/N: 99511-100 NSN: 1730-01-482-1317
replaced by
P/N: 121233-100 (NSN: 1730-01-482-1317)
APPLICATION
Standard equipment for loading/unloading & transporting of aerial stores including munitions, fuel tanks, pylons, special weapons, & SAR packs weighing up to 7,000 lbs onto/into tactical aircraft.
MUNITIONS HANDLING AND LOADING UNIT (MHU-83D/E & MHU-83E BOMB LOADERS)
OPERATIONAL STATUS: Qualification tested per USAF specification MIL-T-38646 REV. C Certified for handling nuclear weapons in accordance with requirements of USAF Weapons Laboratory, Kirtland AFB, NM, and USAF/LG – Airforce Manual 91-118 Safety design and Evaluation Criteria for Nuclear Weapons Systems.
P/N 8141050-70 (NSN 1730-01-491-1557)
APPLICATION (Model: MJ-1C)
Standard equipment for loading/unloading & transporting of aerial stores including munitions, fuel tanks, pylons, special weapons, & SAR pack weighing up to 3,000 pounds onto/into tactical aircraft.
AERIAL STORES LIFT TRUCK (MJ-1C BOMB LOADERS)
OPERATIONAL STATUS: Environmental tested per MIL-E-4970 (-65oF to 160oF). Qualification tested to insure compliance with the MJ-1A test requirements. Certified for handling nuclear weapons in accordance with requirements of USAF Weapons Laboratory, Kirtland AFB, NM. EMI tested and qualified for Radiated Emissions (RE102), and Radiated Susceptibility (RS103) per MIL-STD-461D and MIL-STD-462D. CE certified per European Machinery Directives and Standards of EN60204-1:1997. Engine exhaust emission is certified to TIER 2 of European Emission Standards. Noise emission is limited to less than 80dBA at one meter distance of the unit or operator station per latest issue of ISO 3744.
FA-50 (Aviation Ground Support Equipment)
LINKLESS AMMUNITIONS LOADING SYSTEMS (LALS)
P/N: 029999-3
P/N: 3141AS798-1
(NSN: 1730‐01‐504‐6347)
LALS is the next generation and latest development
in ground support equipment for storing, transporting
and loading 20mm rounds into the Air Force aircraft gun
system while downloading and restoring empty cases and unfired rounds. The ammunition loader interfaces with the F-15, F-16 or F-22 aircraft M61A 1 gun system.
*
GFU-24A/E32K-7 (P/N: 3305AS1400-1) is a cross-platform,
service, mobile ammunition transfer system for loading and
unloading 20mm ammunition from the ALS, UALS, LALS II,
or LALS 3 Linkless Ammunition Loading Systems. Capable of
being crank or pneumatically with an air ratchet, the 7 can load
new 20mm ammunition into the LALS while simultaneously
downloading unexpected ammunition into the spent casings.
The unexpended ammunition is unloaded into a tray for returning to bulk ammunition storage containers while spent casings are dropped out of the system into bulk cans below the Unit. The removable frame assembly can be removed for deployments where the entire structure is not required and can be mounted on the aft of the USN/USMC LALS II with included arm sections. The GFU-24A/E32K-7 incorporates an auto-detection system that automatically stops the system is an empty space occurs during loading. The system can also be operated in forward and reverse direction when cycling the system and not loading.
*
FA-50 (Aviation Ground Support Equipment)
CABIN PRESSURIZATION AND LEAKAGE TESTER
Qualified and in-service with the USAF, USN, USMC. Services all rotary and fixed wing military and commercial aircraft.
Flow 400 SCFM
Diesel Engine Drive (AF/M32T-1, P/N: 93038-100, NSN: 4920-01-381-4950
Flow 400 SCFM
Electric Motor Driven (AF/M24T-3, P/N: 78011-100, NSN: 4920-01-063-0120)
Electric Motor Driven (AF/M24T-3, P/N: 96384-100, NSN: 4920-01-435-8545)
*
FA-50 (Aviation Ground Support Equipment)
USAF Acquisition Program for UHTS:
HII ‘s new generation of Universal Hydraulic Test Stand (UHTS) with the latest state-of-the-art features and components. UHTS utilizes a high resolution LCD Display HMI (Human Machine Interface) with resistive touch screen for operation and monitoring of UHTS System and functions. HII is currently on Contract with USAF to build UHTS. Accepted in-service by USAF for supporting their F-16 and can be used to support any transport or fighter aircraft or helicopter in their inventory.
P/N: 101198-100
NSN: 4920-01-591-9361RN
Flow Rate Capacity:
One System: 53 GPM at 3000 PSI, 40 GPM at 4000 PSI, 32 GPM at 5000 PSI per system
Two System: 106 GPM at 3000 PSI, 80 GPM at 4000 PSI, 64 GPM at 5000 PSI Or combined
UHTS comes with an integral built Hydraulic Purification System (HPS) that provides continuous cooling, filtering moisture and to remove hydraulic fluid particulates, water, chlorinated solvents, absorbed air & gases removal from hydraulic fluid. Keeping hydraulic fluid clean and eliminates the need of changing hydraulic fluid for a long period of time. HPS work in a very cost-effective way to minimize hydraulic fluid usage, minimize hazardous waste disposal needs, reduce deployment foot print and sharply reduce hydraulic maintenance and associated costs.
USAF Hydraulic Purification Articles:
Purification Performance
1) Contaminant removal: 55 gallon of hydraulic fluid in 5 hours.
2) Water: From 1000 to less than 200 PPM.
3) Chlorinated solvents: From 400 to less than 100 PPM.
4) Air & Gas: 100% dissolved air removal, 98% (by volume) removal.
5) Particulate: Cleanliness level equal to or better than NAS 1638 class 3.
P/N: 101197-100
NSN: 4920-01-592-0750RN
One System: 53 GPM at 3000 PSI, 40 GPM at 4000 PSI, 32 GPM at 5000 PSI per system
Two System: 106 GPM at 3000 PSI, 80 GPM at 4000 PSI, 64 GPM at 5000 PSI Or combined
UHTS comes with an integral built Hydraulic Purification System (HPS) that provides continuous cooling, filtering moisture and to remove hydraulic fluid particulates, water, chlorinated solvents, absorbed air & gases removal from hydraulic fluid. Keeping hydraulic fluid clean and eliminates the need of changing hydraulic fluid for a long period of time. HPS work in a very cost-effective way to minimize hydraulic fluid usage, minimize hazardous waste disposal needs, reduce deployment foot print and sharply reduce hydraulic maintenance and associated costs.
Purification Performance
1) Contaminant removal: 55 gallon of hydraulic fluid in 5 hours.
2) Water: From 1000 to less than 200 PPM.
3) Chlorinated solvents: From 400 to less than 100 PPM.
4) Air & Gas: 100% dissolved air removal, 98% (by volume) removal.
5) Particulate: Cleanliness level equal to or better than NAS 1638 class 3.
UHTS is set-up with Instruments capability to be verified by an inexpensive Instrument Verification Set (IVS) within 15 minutes minimizing UHTS downtime and cost. All readings on UHTS are shown on high resolution LCD Display & Engine Performance Module. NO GAUGES including Transducers or Flowmeters are required to be removed for calibration. IVS can be connected directly to UHTS to verify that Transducers & Flowmeters are within acceptable accuracy. IVS is certified and traceable to NIST.
ITEM |
SPECIFICATIONS |
MJ-2A |
UHTS
|
1 |
Design |
30 years old Technology, number of major component are obsolete. |
New generation of Hydraulic Test stands with the latest state-of-the-art features and components. UHTS has also been qualified to the most rigorous military requirement testings such as environmental, Electro Magnetic Interference, Mobility, Reliability, Maintainability, etc. |
2 |
Aircraft Application |
Accepted in-service by USAF for their F-16 and some designated aircraft. |
Accepted in-service by USAF for supporting their F-16 and can be used to support any transport or fighter aircraft in their inventory. |
3 |
Hydraulic Purification System (HPS) |
Using normal Filter Elements. |
UHTS comes with an AF qualified integral built Hydraulic Purification System (HPS) that provides continuous cooling, filtering to remove hydraulic fluid particulates, water, chlorinated solvents, absorbed air & gases from aircraft hydraulic fluid as well as test stand. This purification process eliminates the need of changing hydraulic fluid for a long period of time. HPS works in a very cost effective way to minimize aircraft hydraulic fluid usage, minimize hazardous waste disposal needs, reduce deployment foot print and sharply reduce aircraft hydraulic components maintenance and associated costs. (See attached article from USAF, which is self-explanatory.) Purification Performance 1) Contaminant removal: 55 gallons of hydraulic fluid in 5 hrs. 2) Water: From 1000 to less than 100 PPM 3) Chlorinated solvents: From 400 to less than 100 PPM 4) Air & Gas: 100% dissolved air removal, 98% (by volume) removal 5) Particulate: Cleanliness level equal to or better than NAS 1638 class 3. |
4 |
Test Medium |
Hydraulic fluid, MIL-H-5606, MIL-H-83282 |
Hydraulic fluid, MIL-PRF-5606, MIL-PRF-83282, and MIL-PRF-87257. |
5 |
Flow Rate Capacity |
One system 35 GPM at 3000 PSI 15 GPM at 5000 PSI Two system 70 GPM (35 GPM/system at 3000 PSI) 30 GPM (15 GPM/system at 5000 PSI) or combined |
One system 53 GPM at 3000 PSI 40 GPM at 4000 PSI 32 GPM at 5000 PSI per system Two system 106 GPM at 3000 PSI 80 GPM at 4000 PSI 64 GPM at 5000 PSI Or combined |
6 |
Operating Conditions
|
Ambient Temperature Range -40ºF to +125ºF Altitude: Sea level to 6000 feet Relative Humidity: 0% to 100% Test Stand Position: Up to 8 1/2° from horizontal |
Ambient Temperature Range -40ºF to +125ºF Altitude: Sea level to 7000 feet Relative Humidity: 0% to 100% Test Stand Position: Up to 8 1/2° from horizontal |
7 |
Hydraulic Reservoir
|
60 U.S. Gallon capacity vented to atmosphere and fluid is subject to ambient |
90 U.S. Gallon capacity Is completely sealed to atmosphere. This feature prevents airborne particulate, moisture and air to enter hydraulic fluid, maintaining purity of hydraulic fluid all the time.
|
8
|
Control Panel |
Conventional Control and Analog Instrumentation |
Combination of manual and automated controls. Fully military qualified with System Diagnostic, Built-in Test System and Human Machine Interface Touch Screen Operator Panel enabling ease of Operator Operation, Troubleshooting and ease of Calibration. |
9
|
Drive Unit |
Diesel Engine, 210 HP, naturally aspirated, non-EPA certified, obsolete |
Diesel Engine, 300 HP, turbo-turbo charged, EPA certified to TIER III, Multi Fuel. |
10 |
Engine Diagnostic System |
No |
Cummins engine QSB6.7 is an electronic fuel and Governor controlled via Electronic Control Module (ECM) and full diagnostic control feature facilitating safety and troubleshooting features. |
11 |
Fuel tank capacity |
42 US gallons |
60 US gallon |
12
|
External Fill and Purification Ports |
No |
External Reservoir Fill and Discharge Ports enables the Operator to fill the Hydraulic Reservoir from an outside source, or to remove clean filtered hydraulic fluid from the Reservoir also External Purification Ports allow purification of external fluid source. |
13 |
Back Pressure Regulator |
No |
Back Pressure Regulator allows operation in both aircraft (Closed Loop) or test Stand Reservoir (Open Loop) operation with pressurized or non-pressurized aircraft reservoir systems. |
14 |
Instrument Calibration/Verification |
All Instruments require removal and verified calibration by third party, these results in equipment downtime and excessive cost. |
UHTS is set-up with Instruments capability to be verified by an inexpensive Instrument Verification Set (IVS) within 15 minutes minimizing Equipment downtime and cost. |
15 |
Fault Diagnostic System |
No |
If a fault exists before system operation or a fault occurs during system operation, fault conditions will immediately report to HMI message field and warning horn is activated. Any fault condition will be permanently stored to retentive memory of HMI computer. Up to 200 fault conditions can be stored in retentive memory If a critical fault occurs during system operation, engine will be automatically shut down in 10 seconds. Each fault condition has a corresponding fault diagnostics page at HMI. Fault diagnostics page provides detail fault information and recommend corrective actions. |
16 |
115 VAC Utility Power |
No |
UHTS incorporates Invertor to provide 115 VAC, Single Phase Electrical Power for Utilities. |
17 |
Wet Weight |
6,3000 Lbs |
7,800 Lbs |
All stated Specifications are subject to change.
High Purity Self Generating Nitrogen Service Cart
(HP-SGNSC)
Diesel Engine Driven
P/N: 130009-100
NSN: 3655-01-621-3426
Hydraulic International, Inc. (HII) was awarded a Contract to supply up to 300 Units of High Purity Self Generating Nitrogen Servicing Carts (HPSGNSC), NSN: 3655-01-545-4410 and 3655-01-545-2483 worth Total Estimated Amount of $42,351,675.00. These units are self-contained, towable, high purity carts that produce gaseous nitrogen at a 99.5% purity level, a pressure of 5000 psi, and high flow of not less than 30 Standard Cubic Feet per Minute (SCFM) in both diesel and electric power configurations, with oil free design compressors and pressure boosters eliminate the need for oil separators, as a result extending the life of the nitrogen separation membranes, eliminating oil filter change, maintenance resulting in reduction of the overall life cycle cost of the HPSGNSC.
See Solicitation Number: FA8533-12-R-30143 (US Air Force)
https://govtribe.com/project/high-purity-self-generating-nitrogen-servicing-cart-hp-sgnsc
FA-50 (Aviation Ground Support Equipment)
Title and Designation | HII Part Number | NSN | |
1 | Hydraulic Purification Unit | 100033-100 | 4330-01-587-5425 |
2 | Universal Hydraulic Test Stand (UHTS), Diesel | 101197-100 | 4920-01-592-0750RN |
3 | Universal Hydraulic Test Stand (UHTS), Electric | 101198-100 | 4920-01-591-9361RN |
4 | Instrument Verification System (IVS) | 101199-100 | 4920-01-607-2985 |
5 | Linkless Ammunition Loader (LALS) | 029999-3 | 1730-01-428-4275 |
6 | Ammunition Replenisher Transfer System | 3305AS1400-1 | 4925-01-536-8673 |
7 | Munition/Handling Loading Unit, MHU-83D/EDiesel Engine Driven | 971480-30 | 1730-01-446-2422 |
8 | Munition/Handling Loading Unit, MHU-83EElectric Driven, Battery Powered | 121233-100 | 1730-01-482-1317 |
9 | Aerial Stores Lift Truck, Diesel Driven, MJ-1C | 8141050-70 | 1730-01-491-1557 |
10 | Aerial Stores Lift Truck, Electric Driven, MJ-1E | 050025-100 | 1730-01-536-6388 |
11 | Aircraft Cabin Leakage Tester, 400 SCFM, Electric Driven | 96384-100 | 4920-01-435-8545 |
12 | Aircraft Cabin Leakage Tester, 400 SCFM, Diesel Engine Driven | 93038-100 | 4920-01-381-4950 |
13 | Portable Hydraulic Fluid Servicing Unit, PMU-71/E | 061481-100 | 3040-01-546-5962 |
14 | Portable Engine Oil Servicing Unit, PMU-72/E | 061475-100 | 3040-01-546-4129 |
15 | Portable Transmission Fluid Servicing Unit, PMU-73/E | 061477-100 | 3040-01-546-4146 |
16 | Portable Rotor Fluid Servicing Unit, PMU-74/E | 061479-100 | 3040-01-546-4126 |
17 | Hydraulic Fluid Servicing Unit, Filler and Pressurization, 0-3000 PSI Output Pressure, HSU-1-3K | 080026-100 | 4910-01-602-5069 |
18 | Aircraft Ground Power Unit, Diesel Engine Driven | GPU-D-60KVA-28VDC-300 | 2815-01-597-1322 |
19 | High Purity Self Generating Nitrogen Servicing Cart (HP-SGNSC), Diesel Version | 130009-100 | 3655-01-621-3426 |
20 | High Purity Self Generating Nitrogen Servicing Cart (HP-SGNSC), Electric Version | 130010-100 | 3655-01-621-3781 |
21 | Instrument Contamination System/Hose Flushing Manifold (ICS/HFM) | 101199-500 | 4920-01-654-1985 |
22 | Universal Hydraulic Components Test Stand | MHCA/F27T-12P&MTCA/E27T-14 | 4920-01-579-88234920-01-615-9021 |
FA-50 (Aviation Ground Support Equipment)